VISS Fire Resistant Facade System
Overview
The VISS Fire system keeps the glass in the right position in the event of fire with a wide range of additional components, such as fire-proof anchors, stainless steel clamping sections etc. to prevent the entry of fire and smoke. Numerous projects and a host of international tests and approvals in classes E30, EI30, EI60, EI90 attest the reliability of VISS Fire with respect to thermal insulation and fire protection.
Technical Specifications
- - Materials/surface finishes
- - Uncoated steel or hot-galvanised strip steel, suitable for powder-coating or stove enamelling
- - Support structures
- - VISS system profile
- - Designer profiles (Linea)
- - Construction types
- - Mullion-mullion-transom construction
- - Mullion-transom-mullion construction
- - Welded and/or push-fit construction
- - Segmental glazing
- - Equipment
- - Doors with curtain walls
- - Special technical features
- - Face width 50 mm
- - Installation depths 50 - 140 mm
- - Thickness of infill elements, 5 - 70 mm
Application Areas
- - Airports, hospitals, hotels, shopping malls, railway stations, banks, administrative buildings, cultural centers and all outdoor areas
Material Information
Steel
Documents
- Tested in accordance with EN 1364
- Fire protection classes E30
- E60
- Fire protection classes EI30
- EI60
- EI90
- TRAV
- Product standard curtain wall in accordance with EN 13830
- Clamp connection AbZ Z-14.4-465
- Mullion-transom connection AbZ Z-14.4-467
- Swiss fire protection approvals
Jansen AG Products
Metal Curtain Walls
Request a quote for this product
Jansen AG
VISS Fire Resistant Facade System