☎ Contact Us · +90 (850) 303 27 83
Yapı Kataloğu light+intelligent süper eng

VISS Fire Resistant Facade System

Overview
The VISS Fire system keeps the glass in the right position in the event of fire with a wide range of additional components, such as fire-proof anchors, stainless steel clamping sections etc. to prevent the entry of fire and smoke. Numerous projects and a host of international tests and approvals in classes E30, EI30, EI60, EI90 attest the reliability of VISS Fire with respect to thermal insulation and fire protection.

Technical Specifications

  • - Materials/surface finishes
  • - Uncoated steel or hot-galvanised strip steel, suitable for powder-coating or stove enamelling
  • - Support structures
  • - VISS system profile
  • - Designer profiles (Linea)
  • - Construction types
  • - Mullion-mullion-transom construction
  • - Mullion-transom-mullion construction
  • - Welded and/or push-fit construction
  • - Segmental glazing
  • - Equipment
  • - Doors with curtain walls
  • - Special technical features
  • - Face width 50 mm
  • - Installation depths 50 - 140 mm
  • - Thickness of infill elements, 5 - 70 mm

Application Areas

  • - Airports, hospitals, hotels, shopping malls, railway stations, banks, administrative buildings, cultural centers and all outdoor areas

Material Information

Steel

Documents

  • Tested in accordance with EN 1364
  • Fire protection classes E30
  • E60
  • Fire protection classes EI30
  • EI60
  • EI90
  • TRAV
  • Product standard curtain wall in accordance with EN 13830
  • Clamp connection AbZ Z-14.4-465
  • Mullion-transom connection AbZ Z-14.4-467
  • Swiss fire protection approvals
Metal Curtain Walls